Buy ANSI A PERFORMANCE STANDARDS FOR KITCHEN AND VANITY CABINETS from SAI Global. Buy KCMA A Performance And Construction Standard For Kitchen And Vanity Cabinets from SAI Global. Kitchen and vanity cabinets bearing the ANSI/KCMA A certification seal have been extensively tested for their structural integrity, drawer.

Author: Dizragore Nektilar
Country: Zambia
Language: English (Spanish)
Genre: Automotive
Published (Last): 22 January 2018
Pages: 381
PDF File Size: 14.13 Mb
ePub File Size: 18.42 Mb
ISBN: 478-4-19663-951-7
Downloads: 6371
Price: Free* [*Free Regsitration Required]
Uploader: Mobar

To test the ability of the finish to withstand high heata cabinet door is placed in a hotbox at F and 70 percent ansj humidity for 24 hours.

The strength behind certified cabinetry: ANSI/KCMA A161.1

Skip to main content. Scroll Down for more stories. To test the ability of the drawer-front assembly to withstand the impact of closing the drawer under normal use, a 3-pound weight is dropped 8 inches against the drawer assembly. Cabinet doors are weighted with 65 pounds and operated 10 times to test the ability of door and hinges to withstand loading.

Finish is exposed to vinegar, grape juice, olive oil, lemon juice, proof alcohol and more to ensure no appreciable discoloration, stain or whitening of the finish occurs. A 3 pound weight is dropped 10 times against the drawer assembly to ensure that the drawer front assembly z161.1 withstand the impact of closing.

After 10 drops, there must be no evidence of looseness or structural damage to the drawer-front assembly that impairs its operation. To test the ability of the finish to withstand long periods of exposure to aansi detergent and water solution, a cabinet door edge is subjected to exposure to a standardized detergent formula for 24 hours.

For information on the certification or to locate a certified cabinet manufacturer, visit the Certifications portal at KCMA. This ensures the cabinets will live up to your expectations. These include participation and review by consumer and supplier organizations, builders, remodelers, the U.

The weighted door is slowly operated for 10 cycles from 90 degrees open to 20 degrees open, and returned to the degree position.

  COMPANIES IN SRIPERUMBUDUR SIPCOT PDF

KCMA Certified

The drawers must then remain operable with no failure in any part of the drawer assembly or operating system, and drawer bottoms must not be deflected to interfere with drawer operation.

KCMA has sponsored the nationally recognized cabinet testing and certification program for more than 45 years. Have something to say?

Doors are opened and closed for 25, cycles to ensure durability under the stress of normal usage. In order to be certified, cabinets must also undergo eight categories of testing, covering structural integrity, drawer and door operation and finish quality see sidebar below.

To test the ability of the finish to withstand substances typically found in the kitchen and bath, exterior exposed surfaces of doors, front frames, drawer fronts and end panels are subjected to vinegar, lemon, orange and grape juices, tomato catsup, coffee, olive oil, and proof alcohol for 24 hours and to mustard for one hour.

The strength behind certified cabinetry: ANSI/KCMA A | Woodworking Network

For more information on the certification process, or to find manufacturers of certified cabinetry, visit KCMA. A hour soap and water solution test checks the finish’s ability to withstand exposure to detergents and moisture. In addition, mounted wall cabinets are gradually loaded to pounds to ensure no visible sign of failure in the cabinet or the mounting system. After the test the drawer must not be damaged and must operate as before the test, with no visible sign of joint separation or failure of any part of the cabinet or mounting system.

Shelves and bottoms are loaded at 15 pounds per square foot to ensure no excessive deflection or joint failure on the cabinet or mounting system. To test the ability of shelves, bottoms and drawer bottoms to withstand the dropping of cans and other items, a 3-pound steel ball is dropped from 6 inches above the surface. To test the ability of cabinet doors and connections to withstand impacts such as children may cause in falling against a cabinet, or anxi into it with a tricycle, a pound sandbag is used to strike the center of a closed cabinet door and repeated with the door opened to a ans angle.

  AUDIOGRAM FAMILIAR SOUNDS PDF

These verify the structural integrity and strength of the cabinets. The exceptions are sink fronts and bases, oven cabinets and refrigerator cabinets.

Welcome to our redesigned homepage! The door must remain weighted for 10 minutes, after which the door and hinges must show no visible signs of damage, and connections between cabinet-and-hinge and door-and-hinge must show no sign of looseness.

The finish must then show no appreciable discoloration and no evidence of blistering, cold checking, or other film failure.

Mastercraft Cabinets | KCMA Certification Program, ANSI Standards

Please refine your selection. To test the ability of the finish to w ithstand hot and cold cycles for prolonged periods, a cabinet door is placed in a hotbox at F and 70 percent relative ansk for one hour, removed and allowed to return to room temperature and humidity conditions, and then placed in a coldbox for one hour at -5F. To test the ability of doors, door-holding devices, hinges and attachment devices to operate under the stress of normal use, doors are opened and closed through a full degree swing for 25, cycles.

The door edge must then show no delamination or swelling and no appreciable discoloration or evidence of blistering, checking, whitening, or other film failure. The maximum number of products that can be compared is 4.