AAMA 502 08 PDF

most recent revision of the AAMA and. field testing protocols. AAMA 08,. “Voluntary Specification for Field Testing of. Newly Installed Fenestration. The AAMA (Voluntary Specification for Field Testing of Newly Installed Fenestration Products) is a field-testing guide developed by the American. AAMA Voluntary Specification for field testing of newly installed fenestration products. Includes Air Infiltration and Water Penetration.

Author: Aracage Telrajas
Country: France
Language: English (Spanish)
Genre: Literature
Published (Last): 20 January 2007
Pages: 133
PDF File Size: 9.99 Mb
ePub File Size: 13.36 Mb
ISBN: 515-2-68026-226-9
Downloads: 29259
Price: Free* [*Free Regsitration Required]
Uploader: Zolosho

This allows us to not only properly test fenestrations on new construction projects, but also pinpoint the cause of any 5022 failures and provide accurate recommendations to achieve successful testing results. The number of tests depends on the size and budget of the project. If you are looking for a reputable second or third-party testing company to perform accurate professional testing, provide concise reports, and help you through the azma process, contact BDG today.

If you have any questions pertaining to field testing specifications on your aams, or simply need a quote, do not hesitate to call or email anytime and we would be glad to assist you the best we can. The AAMA is the first edition of this voluntary guideline.

It is primarily used for new construction quality control and assurance purposes.

MISSION Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset. The project architect, manager, or owner specifies the amount and locations of the windows to be tested; this happens either early in the project or at three intervals in the case of large projects: The AAMA is the proper test method for field testing of storefronts, curtain walls and sloped glazing for air leakage and water penetration resistance performance.

  ASTM D4585 PDF

The only problem with the verbiage provided is that it is often inserted in a generic format that does not provide details as to the areas, quantity, and specific testing pressures. BDG has extensive knowledge of most building systems and specializes in forensic water intrusion investigations. A predetermined amount of air leakage is allowable; however, no water leakage is permitted at all. Testing shall be performed by an AAMA accredited independent testing agency.

AAMA Water Spray Testing

The specification is for quality 088 water penetration testing only. These specifications establish the requirements for test specimens, apparatus, sampling, test procedures and test reports to be used in evaluating the performance of installed windows and sliding glass doors hereafter referred to as “windows”. Building Diagnostics Group, Inc. If the window installation was completed within 6 months, and there is not a building occupancy permit COthen the AAMA is the right document to use.

These specifications establish the aaka for field test specimens, apparatus, sampling, test procedures and test reports to be used in verifying the air infiltration resistance performance and water penetration resistance performance of installed new windows and sliding glass doors hereafter referred to as “fenestration products”.

The objective of forensic water spray testing is to identify and track the water migration through the simulation of wind driven rain events. For window and door manufacturers, the procedure provides a uniform approach for dealing with different code jurisdictions and specific design pressure for each size of fenestration product opening.

The testing procedure outlined in the AAMA It has become the gold standard for all water penetration resistance testing conducted in 5502 United States in regards to fenestration products such as windows, doors, and skylights.

Before testing, the window installation is visually observed. It is up to the contractor to ensure these testing parameters are established. This guideline is for forensic or investigative water spray testing only. This field check is not appropriate for testing operable components.

  CORRE CONEJO UPDIKE PDF

This specification is for quality assurance water penetration testing only. How is the installation quality? The AAMA can be aamq if the project requires investigative testing. In addition, the AAMA guide provides verbiage that can be directly inserted into project aam, saving time and effort.

Read more about what our customers have to say Member discount will be reflected after successful login to the Checkout process. Field testing and forensic leak investigation services are provided nationwide.

Our field consultants are properly trained and knowledgeable of all testing standards. We provide testing services throughout the United States from our headquarters located in Atlanta, GA.

Water penetration observed when testing windows will be given extra attention for the remainder of the project.

See our AAMA page for additional information. This specification establishes the requirements for field test specimens, apparatus, sampling, test procedures and test reports to be used in verifying the air infiltration resistance performance and water penetration resistance performance of newly installed fenestration products.

AAMA Pubstore Product Listings –

SITC utilizes isolation techniques to assist in identifying the source or sources of the reported water leakage. One-week notice prior to water testing is usually given to all construction crew members concerned with window installation.

A specified pressure is maintained while any escaping air is measured. Is the window square? Begin your publication search by entering information into the fields aqma. Give us a call to discuss your next project.